Timeline
06/03/13:
- 00:33 Ticket #26 (NCL-2001 thermal derate flapping under load (Tyne Bridge gantry)) updated by
- 48h on the analyser, no repro, thermistor in tolerance. Closing …
06/02/13:
- 00:11 Ticket #28 (WBAN acquisition threshold drift in the GAT sector after ...) updated by
- Conductivity histograms are bimodal — one mode below threshold. …
05/22/13:
- 00:33 Ticket #24 (IIS worker process recycling under load; escalated to Microsoft support) updated by
- Microsoft came back: known issue in that filter version, private …
05/19/13:
- 00:22 Ticket #27 (Herring gull nesting in the car-park barrier mechanism; barrier stuck up) updated by
- Nest relocated under licence once vacated, housing screened, hawk kite …
- 00:00 Ticket #28 (WBAN acquisition threshold drift in the GAT sector after ...) created by
- Enrolled-subject acquisition on the GAT sector fell ~12% after the …
05/16/13:
- 00:11 Ticket #27 (Herring gull nesting in the car-park barrier mechanism; barrier stuck up) updated by
- It has eggs in it now. We're legally not allowed to move it, so the …
05/15/13:
- 00:00 Ticket #27 (Herring gull nesting in the car-park barrier mechanism; barrier stuck up) created by
- A herring gull built a nest inside the compound car-park barrier …
05/07/13:
- 00:22 Ticket #26 (NCL-2001 thermal derate flapping under load (Tyne Bridge gantry)) updated by
- It's a thermistor on a wire, Pike. There is no DNS involved in a …
05/06/13:
- 00:11 Ticket #26 (NCL-2001 thermal derate flapping under load (Tyne Bridge gantry)) updated by
- Could the derate flag be a bad reading coming back over DN—
- 00:00 Ticket #26 (NCL-2001 thermal derate flapping under load (Tyne Bridge gantry)) created by
- NCL-2001 (ANPR gantry, Tyne Bridge southbound) intermittently asserts …