LeafNut firmware watchdog reset loop after an OTA rollback

Reported by: People & Places Owned by: S. Rao (Node Control)
Priority: P3 Milestone:
Component: Node Controller / Firmware Version:
Keywords: Cc:
Desk: Estate & Systems Legacy ref: DEVCON-1810

Description

A batch of LeafNut controllers entered a watchdog reset loop after an OTA rollback: the rolled-back image and the config schema mismatched, the controller failed schema validation on boot, watchdog fired, repeat. Nodes cycled every ~40s, never joining the mesh.

Attachments (0)

Change History (3)

comment:1 by D. Pike, 13 years ago

Can't reach the registry after reboot — DNS?

comment:2 by S. Rao, 13 years ago

They never get far enough to try, Pike. They fail schema validation before the network stack is even up.

comment:3 by S. Rao, 13 years ago

Pushed a matching schema ahead of the image, staged the rollback properly. Loop cleared across the batch. Closing.