#48 RESOLVED fault
ICNIRP thermal-only compliance flag stuck AMBER on 14 columns
| Reported by: | People & Places | Owned by: | Regulatory Alignment |
|---|---|---|---|
| Priority: | P3 | Milestone: | |
| Component: | Compliance / Regulatory | Version: | |
| Keywords: | Cc: | ||
| Desk: | Estate & Systems | Legacy ref: | DEVCON-1902 |
Description
Fourteen columns reported their ICNIRP 'thermal-only' compliance flag stuck at AMBER rather than GREEN in the CMS — a stale self-assessment attribute, not an actual excursion — but AMBER blocked the automated compliance return, which must read GREEN.
Attachments (0)
Change History (2)
comment:1 by , 13 years ago
comment:2 by , 12 years ago
Vendor patched the attribute refresh; all 14 flags back to GREEN, compliance return clean. Closing.
Note:
See TracTickets
for help on using tickets.
Attribute-plumbing fault, not an exposure event. (Any genuine biological-effect finding is logged 'anomalous' and referred to Legal, not fixed here.) Chasing the CMS vendor for a patch.